SILENCE SENSOR
[Current Store(ja)][Selection Guide][System Diagram]
[Catalog]
Multi channel emergency broadcasting system
Maximum stereo 32ch
Detect a silence state and source switch
Autostart emergency machine
Test mode
Contact output for alarm
5 points of LED level meters
19 inches 3U size size
PMS440 is a system for emergency broadcasting of 32 stereo channels by maximum configuration.
It detects a silence state of the program source and is a system making automatic change with program output to an emergency source.
When a program source breaks off more than setting time, Silence sensor operates and turns on a relay contact of the alarm output and outputs play contact for emergency machines.
In addition, it turns on a relay contact for PLAY commands of the emergency source equipment at the same time.
“Silence sensor”
It provides for each sensor module with 5 points of LED level meters and can set the silence detection time of the program source and the setting of the threshold level in the range of 10 sec to 90 sec and -20dBu to -60dBu in a module.
In addition, it can switch it to an emergency source with TEST button every each channel forcibly.
The sensor can prohibit an action every each channel.
“Alarm output”
When a program source breaks off more than setting time, Silence sensor operates and turns on a relay contact of the alarm output and outputs play contact for emergency machines.
“Reset”
It uses the system reset button of the master module to return a system in normal state.
Please make this operation after confirming that a program signal is input normally with the level meter of each channel.
Silence sensor is initialized when it continues pressing the system reset button of the master module more than 1 second.
“Others”
PMS440 is modular construction of 2 channel units, and, please specify the number of the channels necessary.at the time of the order.
In addition, the programmed input/output is bypassed by a relay when a power supply is down.
Please refer about the manufacturing of specifications and the patch bay except the standard and the connection cable.
■ Specifications
•PROGRAM INPUTS: BALANCED, +4dBu
•PROGRAM OUTPUTS: BALANCED, +4dBu
•I/O CONNECTORS: ELCO90P-M
•DEFAULT THRESHOLD: -40dBu
•DEFAULT DETECT TIME: 30 sec
•DEFAULT SENSOR STATE: ON
•DEFAULT LEVEL METER REFERENCE: +4dBu
•LEVEL INDICATOR: -10, -5, 0, +3, +6 in dB
•ALARM CONTACT: 24VDC, 100mA
•MACHINE CONTACT: 24VDC, 100mA, 500mS closeing
•FREQUENCY RESPONSE: 20~20kHz ±1dB
•MAINS: 100VAC 50/60Hz, MAX=50W
•DIMENSIONS: 483Wx132.5Hx350D 12Kg
PMS440 "Program Input 1-12" ELCO90-M ch + - 0 Description 1 A H R PROGRAM INPUT 1L 2 B J S PROGRAM INPUT 1R 3 C K T PROGRAM INPUT 2L 4 D L U PROGRAM INPUT 2R 5 E M V PROGRAM INPUT 3L 6 F N W PROGRAM INPUT 3R 7 X AE AM PROGRAM INPUT 4L 8 Y AF AN PROGRAM INPUT 4R 9 Z AH AP PROGRAM INPUT 5L 10 AA AJ AR PROGRAM INPUT 5R 11 AB AK AS PROGRAM INPUT 6L 12 AC AL AT PROGRAM INPUT 6R 13 BJ BS BY PROGRAM INPUT 7L 14 BK BT BZ PROGRAM INPUT 7R 15 BL BU CA PROGRAM INPUT 8L 16 BM BV CB PROGRAM INPUT 8R 17 BN BW CC PROGRAM INPUT 9L 18 BP BX CD PROGRAM INPUT 9R 19 CF CN CW PROGRAM INPUT 10L 20 CH CP CX PROGRAM INPUT 10R 21 CJ CR CY PROGRAM INPUT 11L 22 CK CS CZ PROGRAM INPUT 11R 23 CL CT DA PROGRAM INPUT 12L 24 CM CU DB PROGRAM INPUT 12R
PMS440 "Program Input 13-24" ELCO90-M ch + - 0 Description 1 A H R PROGRAM INPUT 13L 2 B J S PROGRAM INPUT 13R 3 C K T PROGRAM INPUT 14L 4 D L U PROGRAM INPUT 14R 5 E M V PROGRAM INPUT 15L 6 F N W PROGRAM INPUT 15R 7 X AE AM PROGRAM INPUT 16L 8 Y AF AN PROGRAM INPUT 16R 9 Z AH AP PROGRAM INPUT 17L 10 AA AJ AR PROGRAM INPUT 17R 11 AB AK AS PROGRAM INPUT 18L 12 AC AL AT PROGRAM INPUT 18R 13 BJ BS BY PROGRAM INPUT 19L 14 BK BT BZ PROGRAM INPUT 19R 15 BL BU CA PROGRAM INPUT 20L 16 BM BV CB PROGRAM INPUT 20R 17 BN BW CC PROGRAM INPUT 21L 18 BP BX CD PROGRAM INPUT 21R 19 CF CN CW PROGRAM INPUT 22L 20 CH CP CX PROGRAM INPUT 22R 21 CJ CR CY PROGRAM INPUT 23L 22 CK CS CZ PROGRAM INPUT 23R 23 CL CT DA PROGRAM INPUT 24L 24 CM CU DB PROGRAM INPUT 24R
PMS440 "Program Input 25-32 & EMG" ELCO90-M ch + - 0 Description 1 A H R PROGRAM INPUT 25L 2 B J S PROGRAM INPUT 25R 3 C K T PROGRAM INPUT 26L 4 D L U PROGRAM INPUT 26R 5 E M V PROGRAM INPUT 27L 6 F N W PROGRAM INPUT 27R 7 X AE AM PROGRAM INPUT 28L 8 Y AF AN PROGRAM INPUT 28R 9 Z AH AP PROGRAM INPUT 29L 10 AA AJ AR PROGRAM INPUT 29R 11 AB AK AS PROGRAM INPUT 30L 12 AC AL AT PROGRAM INPUT 30R 13 BJ BS BY PROGRAM INPUT 31L 14 BK BT BZ PROGRAM INPUT 31R 15 BL BU CA PROGRAM INPUT 32L 16 BM BV CB PROGRAM INPUT 32R 17 BN BW CC EMERGENCY SOURCE IN L 18 BP BX CD EMERGENCY SOURCE IN R 19 CF CN CW 20 CH CP CX 21 CJ CR CY 22 CK CS CZ 23 CL CT DA 24 CM CU DB
PMS440 "Program Output 1-12" ELCO90-M ch + - 0 Description 1 A H R PROGRAM OUTPUT 1L 2 B J S PROGRAM OUTPUT 1R 3 C K T PROGRAM OUTPUT 2L 4 D L U PROGRAM OUTPUT 2R 5 E M V PROGRAM OUTPUT 3L 6 F N W PROGRAM OUTPUT 3R 7 X AE AM PROGRAM OUTPUT 4L 8 Y AF AN PROGRAM OUTPUT 4R 9 Z AH AP PROGRAM OUTPUT 5L 10 AA AJ AR PROGRAM OUTPUT 5R 11 AB AK AS PROGRAM OUTPUT 6L 12 AC AL AT PROGRAM OUTPUT 6R 13 BJ BS BY PROGRAM OUTPUT 7L 14 BK BT BZ PROGRAM OUTPUT 7R 15 BL BU CA PROGRAM OUTPUT 8L 16 BM BV CB PROGRAM OUTPUT 8R 17 BN BW CC PROGRAM OUTPUT 9L 18 BP BX CD PROGRAM OUTPUT 9R 19 CF CN CW PROGRAM OUTPUT 10L 20 CH CP CX PROGRAM OUTPUT 10R 21 CJ CR CY PROGRAM OUTPUT 11L 22 CK CS CZ PROGRAM OUTPUT 11R 23 CL CT DA PROGRAM OUTPUT 12L 24 CM CU DB PROGRAM OUTPUT 12R
PMS440 "Program Output 13-24" ELCO90-M ch + - 0 Description 1 A H R PROGRAM OUTPUT 13L 2 B J S PROGRAM OUTPUT 13R 3 C K T PROGRAM OUTPUT 14L 4 D L U PROGRAM OUTPUT 14R 5 E M V PROGRAM OUTPUT 15L 6 F N W PROGRAM OUTPUT 15R 7 X AE AM PROGRAM OUTPUT 16L 8 Y AF AN PROGRAM OUTPUT 16R 9 Z AH AP PROGRAM OUTPUT 17L 10 AA AJ AR PROGRAM OUTPUT 17R 11 AB AK AS PROGRAM OUTPUT 18L 12 AC AL AT PROGRAM OUTPUT 18R 13 BJ BS BY PROGRAM OUTPUT 19L 14 BK BT BZ PROGRAM OUTPUT 19R 15 BL BU CA PROGRAM OUTPUT 20L 16 BM BV CB PROGRAM OUTPUT 20R 17 BN BW CC PROGRAM OUTPUT 21L 18 BP BX CD PROGRAM OUTPUT 21R 19 CF CN CW PROGRAM OUTPUT 22L 20 CH CP CX PROGRAM OUTPUT 22R 21 CJ CR CY PROGRAM OUTPUT 23L 22 CK CS CZ PROGRAM OUTPUT 23R 23 CL CT DA PROGRAM OUTPUT 24L 24 CM CU DB PROGRAM OUTPUT 24R
PMS440 "Program Output 25-32 & EMG" ELCO90-M ch + - 0 Description 1 A H R PROGRAM OUTPUT 25L 2 B J S PROGRAM OUTPUT 25R 3 C K T PROGRAM OUTPUT 26L 4 D L U PROGRAM OUTPUT 26R 5 E M V PROGRAM OUTPUT 27L 6 F N W PROGRAM OUTPUT 27R 7 X AE AM PROGRAM OUTPUT 28L 8 Y AF AN PROGRAM OUTPUT 28R 9 Z AH AP PROGRAM OUTPUT 29L 10 AA AJ AR PROGRAM OUTPUT 29R 11 AB AK AS PROGRAM OUTPUT 30L 12 AC AL AT PROGRAM OUTPUT 30R 13 BJ BS BY PROGRAM OUTPUT 31L 14 BK BT BZ PROGRAM OUTPUT 31R 15 BL BU CA PROGRAM OUTPUT 32L 16 BM BV CB PROGRAM OUTPUT 32R 17 BN BW CC EMERGENCY SOURCE OUT L 18 BP BX CD EMERGENCY SOURCE OUT R 19 CF CN CW 20 CH CP CX 21 CJ CR CY 22 CK CS CZ 23 CL CT DA 24 CM CU DB
PMS440 "ERROR CONTACT" D9-M(#4-40) 1 ERROR RELAY CONTACT A 6 ERROR RELAY CONTACT B 2 7 3 8 4 9 5
PMS440 "MACHINE CONTACT" D9-M(#4-40) 1 MACHINE PLAY CONTACT A 6 MACHINE PLAY CONTACT B 2 7 3 8 4 9 5
• Order Information
order number | description | approx. price(US$) |
---|---|---|
PMS440 | 32 stereo, error out, 19” 3U | $5,818 |
PMS440-M | sensor module | $1,545 |
PMS440-F | Sensor frame | $5,818 |
PMS441 | Multi status indicator, 19” 1U | $1,800 |